1. HART - RS232/485 Modbus Converter
-
Links up to four HART instruments
-
HART 7.0 support and backward compatible
-
Transparent HART communication and Modbus RTU
-
RS232 and/or RS485 ports
-
Maps all process variables (PV, SV, TV, QV), diagnostic data, and device status
-
Configurable parameters and custom commands
-
Includes setup software for configuration
Models
GRT-2 Input: HART
Output: 1 x RS485 Modbus
GRT-4 Input: HART
Output: 1 x RS232, 1 x RS485 Modbus
GRT-6 Input: HART
Output: 2 x RS485 Modbus
2. HART - TCP Modbus Converter
-
Reads HART instrument data
-
Acquires one analog and two digital inputs
-
Supports 4–20 mA and 0–5 V analog signal
-
Configurable parameters, range, and zero point
-
Retains configuration settings after power loss
-
Local and remote parameter configuration
-
Allows parameter configuration over Ethernet
-
HART communication and power status LED
Models
HTC-100 Input: 1 x HART
Output: TCP Modbus
HTC-102 Input: 1 x HART, 1 x Analog, 1 x Digital
Output: TCP Modbus
3. Modbus/AD - HART Converter
-
Converts Modbus RTU data into HART device variables
-
Supports an RS485 Modbus RTU interface
-
Converts analog measurements into HART device variables
-
Supports two or four 4–20 mA analog inputs
-
Provides a HART compatible 4–20 mA output
-
Allows configuration of the analog range and zero point
-
Supports local querying and configuration of parameters
Models
MHT-11 Input: RS485 RTU Modbus
Output: HART 4-20mA
MHT-12 Input: RS485 RTU Modbus, 2 x 4-20mA
Output: HART 4-20mA
MHT-14 Input: 4 x 4-20mA
Output: HART 4-20mA
4. HART - RS485 / TCP Modbus Converter
-
Reads 4 HART instruments data
-
Configurable RS485 output port
-
Supports Modbus_RTU and Modbus_TCP
-
Stores acquired data in EEPROM at a configurable interval
-
Retains configuration settings after power loss
-
Supports local and remote parameter queries and configuration
-
Allows parameter configuration over Ethernet
-
Provides power and HART communication status indicators
Models
HTC-200 Input: 1 x HART
Output: 1 x RS485 Modbus
HTC-202 Input: 1 x HART
Output: 1 x RS485 Modbus, TCP Modbus
5. RS232/485 Multi-Channel Converter
-
One serial input from instruments and devices
-
Support transmission of standard Modbus RTU
-
Support non-standard Modbus RTU communications
-
Standard RS232 or RS485 communication interfaces
-
Supports connections of multiple data acquisition devices
-
Adjustable port parameters e.g. baud rate, parity, stop bits
-
Retain configuration settings when power is off
Models
MX-101 Input: 1 x RS232/485 Modbus/non-standard
Output: 3 x RS485 multi-master single slave
MX-102 Input: 1 x RS232/485 Modbus/non-standard
Output: 2 x RS485 multi-master single slave
MX-103 Input: 1 x RS232/485 Modbus/non-standard
Output: 3 x RS485 Modbus protocol
MX-104 Input: 1 x 485 Modbus
Output: 3 x Analog 4-20mA